Item Name: Fluke 115C Field Ture RMS Multimeter
USD 142.88
Quantity: 1
 
Item Code: 0023-0177
 MEMBER BUY ONLY!PLEASE LOGIN
 Ask a question about this
 
 Add my watch 0
 

Fluke 115C Field Ture RMS Multimeter

  Description
 

  0023-0177 
Fluke F115 115C Field Multimeter with backlight.
 

 


 

 

 

Model No.: F115C
Brand: FLUKE

            Large white LED backlight to work in poorly lit areas

  • Resistance and continuity
  • Min/Max/Average to record signal fluctuations
  • CAT III 600 V safety rated

 Specifications

Maximum voltage between any terminal and earth ground

 

 600 V

Surge protection

 

 6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2

Display

Digital:

 6,000 counts, updates 4 per second

Bar graph

 

 33 segments, updates 32 per second

Operating Temperature

 

 -10 °C to + 50 °C

Storage Temperature

 

 -40 °C to + 60 °C

Battery type

 

 9 volt Alkaline, NEDA 1604A/ IEC 6LR61

(NOT INCUDING BATTERY)

Battery Life

 

 400 hours typical, without backlight

 Accuracy Specifications

 

DC millivolts

Range:

 600.0 mV

Resolution:

 0.1 mV

Accuracy:

 ± ([% of reading] + [counts]): 0.5% + 2

 

DC volts

Range/Resolution:

 6.000 V / 0.001 V

Range/Resolution:

 60.00 V / 0.01 V

Range/Resolution:

 600.00 V / 0.1 V

Accuracy:

 ± ([% of reading] + [counts]): 0.5% + 2

 

AC millivolts1 true-rms

Range:

 600.0 mV

Resolution:

 0.1 mV

Accuracy:

 1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz)

 

AC volts1 true-rms

Range/Resolution:

 6.000 V / 0.001 V

Range/Resolution:

 60.00 V / 0.01 V

Range/Resolution:

 600.0 V / 0.1 V

Accuracy:

 1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz)

 

Continuity

Range:

 600 Ω

Resolution:

 1 Ω

Accuracy:

 Beeper on < 20 Ω, off > 250 Ω; detectsopens or shorts of 500 μs or longer.

 

Ohms

Range/Resolution:

 600.0 Ω / 0.1 Ω

Range/Resolution:

 6.000 kΩ / 0.001 kΩ

Range/Resolution:

 60.00 kΩ / 0.01 kΩ

Range/Resolution:

 600.0 kΩ / 0.1 kΩ

Range/Resolution:

 6.000 MΩ / 0.001 MΩ

Accuracy:

 0.9 % + 1

Range/Resolution:

 40.00 MΩ / 0.01 MΩ

Accuracy:

 5 % + 2

 

Diode Test

Range/Resolution:

 2.00 V / 0.001 V

Accuracy:

 0.9% + 2

 

Capacitance

Range/Resolution:

 1000 nF / 1 nF

Range/Resolution:

 10.00 µF / 0.01 µF

Range/Resolution:

 100.0 µF / 0.1 µF

Range/Resolution:

 9999 µF / 1 µF

Range/Resolution:

 100 µF to 1000 µF

Accuracy:

 1.9% + 2

Range/Resolution:

 > 1000 µF

Accuracy:

 5% + 20%

 

Lo-Z Capacitance

Range:

 1 nF to 500 µF

Accuracy:

 10% + 2 typical

 

AC amps true-rms (45 Hz to 500Hz)

Range/Resolution:

 6.000 A / 0.001 A

Range/Resolution:

 10.00 A / 0.01 A

Accuracy:

 1.5% + 3

 

 20 A overload for 30-seconds max

 

DC amps

Range/Resolution:

 6.000 A / 0.001 A

Range/Resolution:

 10.00 A / 0.01 A

Accuracy:

 1.0% + 3

 

 20 A overload for 30-seconds max

 

Hz (V or A input)2

Range/Resolution:

 99.99 Hz / 0.01 Hz

Range/Resolution:

 999.9 Hz / 0.01 Hz

Range/Resolution:

 9.999 kHz / 0.001 kHz

Range/Resolution:

 50 kHz / 0.01 kHz

Accuracy:

 0.1% + 2

 


http://assets.fluke.com/manuals/115C117Cumeng0100.pdf

Notes:
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F
2) Frequency is ac coupled, 5Hz to 30 kHz for ac voltage

Mechanical & General Specifications

Size

 

 167 x 84 x 46 mm (6.57" x 3.31" x 1.82")

Weight

 

 550 g

 

 


 

Photo will have chromatic aberration compared with the product

PACKAGE CONTAIN
1 x FLUKE 115C Digital Multimeter;
1 x Fluke Test lead;
1 x Operation manual in English;       
1 x Carrying case;
(NOT INCUDING BATTERY)

C

 
 


Shipping Address Notice


Turkey & Belgium
Customs Notice


ELECTRIC METER

Cable Tester
Clamp Current Meter
Distance Measurer
Multimeter (Analog)
 
Oscilloscope
 
Hight Accuracy Meters
     
Lux /Light Meter
     
Moisture Tester
   
Radiation Detector
     
Resistance Testers
       
Sound level Meter
       
Tachometers meter
 
Voltage Detectors
 
Weather Meter
 
Energy saving lamps tester
       
SMD Tester
       
Battery Tester
     
Other Tester
 
Test Lead /Probe
UTL02.jpg (120×160)
UTL03.jpg (120×160) UT-L13.jpg (120×160) UTL19.jpg (120×160) UTL23.jpg (120×160) UT-P03.jpg (120×160)
UT-P04.jpg (120×160) UT-P05.jpg (120×160) UT-D04.jpg (120×160) UT-D04.jpg (120×160)  

537

 
TOP
 

Copyright © 2017 409shop walkie talkie All Rights Reserved.    
Surecom_product-line 409shop-site-map 409shop-site-map
Our Company Products Learn & Support Customer Service Partner With Us
Home 2017 COMING SOON  Software Downloads PAY Method Reseller Contact
About Us LED  Technical Support Post Tracking Supplier Contact
My Company DMR Radio FRS Frequency Privacy Policy Affiliate Program
News  Small Mobile FAQ Repair Return Address 寻求供应商
Authority of All   Exchange/Refund/Return Policy Contact Us  
    Tax Policy Free Shipping  
 
Friendly Links            
me-too-online.com daidaisiumui    emori Gift and Premium me-too-online.com me-too-online.com justbuycases
 
www.de-luce.com